What was found
CORROSION ON THE UPPER CAP (PN: 65B38075-3) OF MAIN DECK FLOOR STRUCTURE AT STA 1500, BETWEEN RBL 75.92 AND RBL 98.58 REMOVE AFFECTED FASTENER IAW SRM 51-40-02 REV 94. 2) REPAIR DAMAGE AREA IAW SRM 53-00-51-2R-3 REPAIR 3 REV 94 AND EI T2022A53M-1661 REV 1. 3) INSTALL REPAIR PARTS IAW SRM 53-00-51-2R-3 REPAIR 3 REV 94, EI T2022A53M-1661 REV 1 AND DWG 65B38075 SH5 REV C. 4) JOB COMPLETED AND CONDTION CHECK NORMAL</P>)