As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING THE DEVELOPMENT OF THE TASK CARD HYDRAULIC POWER LEAK CHECK, RH WING, WAS FOUND LEAK EVIDENCE AT THE O/B AILERON LOCKOUT MECHANISM. LEAK TEST WAS PERFORMED ON O/B RH AILERON LOCKOUT MECHANISM AND NO LEAKS FOUND. TEST PERFORMED IAW 29-11-00-796-053, REV 135</P>)