What was found
CORROSION - SKIN, KEEL BEAM ASSEMBLY STRUCTURE, STA 1398, RBL 6(1) REMOVE THE AFFECTED FASTENER IAW SRM 51-40-02 REV 95. 2) BLENEDED OUT THE DAMAGE AREA IAW SRM 51-10-02 REV 95. 3) PERFORM NDT INSPECTION REFER TO JOB CARD ATTACHING SHEET 0324880 & DATA SHEET 7148079-1. 4) ACCOMPLISHED EI T2022A53M-1985 REV 1 & EI ATTACHED TO W/O 7148085. 5) JOB COMPLETED</P>)