What was found
CORROSION-SKIN, FWD CGO COMPARTMENT BILGE SURFACE STA 740~760. S-46R~S-47R(<P>1) BLEND OUT THE DAMAGE AREA I.A.W SRM 51-10-02. REV=52 2) PFM NOT INSP REFER TO JOB CARD ATTACHING SHEET NO=0271928 3) MEASURED REWORK AREA DEPTH=0.005", LENGTH=2", WIDTH=2" IT WAS ALLOWABLE I.A.W SRM 53-00-01-1A-1, TABLE I, DETAIL II, REV=52 4) APPLY PROTECTIVE COATING AT REWORK AREA. I.A.W SRM 51-20-01, REV=52 5) JOB COMLETED.</P>)