As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FOUND L5 DOOR FRAME WEB CRACK AT STA 2231 S21L - S22L(<P>1) REMOVED AFFECTED FASTENERS TO GET ACCESS IAW SRM 51-40-02-0G-0 REV 97. 2) REPAIRED DAMAGE AREA IAW SRM 53-60-15-2R-3 REPAIR 3 REV 97 AND EI T2023A53M-1537 REV 0. 3) INSTALLED FASTENERS IAW SRM 53-60-15-2R-3 REPAIR 3 REV 97 AND EI T2023A53M-1537 REV 0. 4) ACCOMPLISHED IAW EI T2023A53M-1537 REV 1. 5) JOB COMPLETED</P>)