What was found
WATER FILL CONNECTION AREA DOUBLER CORROSION AT STA 980 S45R - S46R(<P>1) REMOVE DAMAGE PARTS IAW SRM 51-40-02-0G-0 REV 97. 2) INSTALL NEW PARTS SRM 51-40-02-0G-0 REV 97, DWG 142U3780 SHEET 12 REV F, DWG 140U0999 SHEET 30 REV -, DWG 142U0130 SHEET 1 REV A AND DWG 417U2400 SHEET 2 REV -. 3) JOB COMPLETED AND CONDITION CHECK NORMAL</P>)