What was found
MDDR 188056, PERMANENT REPAIR OF LH ELEVATOR ON OR BEFORE 25 F/C PER EO 4455A183(<P>1) REMOVE THE DAMAGE MATERIAL, CLEAN & MEASURE THE DAMAGE AREA (L: 8.5", W: 6", D: 3 PLIES, 36" FROM OUTBD EDGE AT T/E) BOND THE 3 REPAIR PLIES (L: 11.5", W: 2.2") WITH FILM ADHESIVE. CURE AT 260F FOR 130 MINUTES WITH MINIMUM VACUUM OF 22 IN/HG IAW SRM 55-20-01-2R-1 REFER TO SRM 51-70-07-0G-0 REV 98. WORK REF SRM 57-53-01-2R-1 REV 98, SRM 51-70-10-2R-2 REV 98 & SRM 51-70-10-2R-0 REV 98 2) CONDITION CHECK IS GOOD</P>)