What was found
BURNING SMELL & VIBRATION ON FINAL. ISOLATED TO PACK 1. NO INDICATIONS, SHUT OFF PACK(<P>PACK 1 PLACED ON DMI 192433 PER MEL 21-51-01-03 & DMI 192434 PER 26-16-01-02-01B (DUE TO PACK 1 INOP). PACK 1 DMI 192433 & FWD LOBE FIRE DETECTION DMI 192434. CHAPTER 5 CONDITIONAL INSPECTION (AMM 05-51-56) CARRIED OUT. LP 1673134 ITEM 3 1SEP23: R/R ACM IAW AMM 21-51-04/401. OPS CHECK GOOD. DMI 192433 CLOSED. LP 1673135 ITEM 4 1SEP23: REACTIVATED SMOKE DETECTORS & OPS CHECK GOOD IAW AMM 26-16-01-404-008.</P>)