What was found
TWO LOWSPEED RTO'S PERFORMED DUE TO L GEN OFF, L/R UTILITY BUS OFF SHORTLY AFTER APPLYING T/O POWER(<P>TRANSFER TO DMI 198358 PER MEL 24-00-01-01 CAT B DUE 06DEC2023. MX ACTIONS COMPLIED WITH VIA DISCONNECTION. PLACARDS INSTALLED. DISPATCH NOTIFIED. PERFORMED HIGH ENERGY STOP INSPECTION PER B767 AMM 05-51-14. NO DEFECTS NOTED. LP 1712717 M5: R/R LH ENG IDG IAW AMM 24-11-01. LEAK & OPS CHECK GOOD. NO FURTHER DEFECTS NOTED. MCC NOTIFIED. THIS CLEARS DMI 198358. PLACARDS REMOVED</P>)