What was found
MDC UPPEN MAIN - AUX SILLS SPLICE TO STRINGERS - BETWEEN STA 412 TO STA 434 ON STRINGER 13, CRACK INDICATION FOUND.(<P>STRINGER SPLICE WAS REPLACED IAW DRAWING 311T1130 & FVCI #23238-1 REV A. NO FURTHER DEFECTS NOTED</P>)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MDC UPPEN MAIN - AUX SILLS SPLICE TO STRINGERS - BETWEEN STA 412 TO STA 434 ON STRINGER 13, CRACK INDICATION FOUND.(<P>STRINGER SPLICE WAS REPLACED IAW DRAWING 311T1130 & FVCI #23238-1 REV A. NO FURTHER DEFECTS NOTED</P>)