As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD TRIM VALVE FAIL.(<P>FWD TRIM VALVE WAS REPLACED IAW AMM 21-61-07-404-011-003 REV. 142 DATE 22 APR 24. TORQUE APPLIED 45 LB-IN S/N 0823900243 DATE 15 NOV 24. BONDING TEST WAS SATISFACTORY 2.2 MILLIOMHMS S/N DC- 005040 DATE 12 DEC 24. OPERATIONAL TEST WAS SATISFACTORY. GOOD FOR SERVICE.</P>)