As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
APU COMPARTMENT AREA LOWER FRONT FIRE WALL BRACKET LOCK AND FIRE WALL WITH WORN.(<P>APU COMPARTMENT AREA LOWER FRONT BRACKET WAS INSPECTED AND ONLY DAMAGE ON FIRE WALL. FIRE WALL WAS REPLACED IAW SRM 51-10-02-0G-0 PAR 9 SRM 51-10-08-02-0G-0 REV 125 15/APR/2024. NO FURTHER DEFECTS NOTED</P>)