What was found
CORROSION DAMAGES ON THE UPPER CHORD OF LH WING FIXED TRAILING EDGE RIB AT ILES 994.50.(<P>1. REMOVED THE AFFECTED FASTENERS IAW SRM 51-40-02-0G-0 REV=60. 2. BLEND OUT THE DAMAGE AREA IAW SRM 51-10-02-0G-0 REV=60. 3. PFM NDT INSP REFER TO JOB CARD ATTACHING SHEET 0458453 AND DATA SHEET 10043936-1. 4. ACCOMPLISHED EI T2024A57M-2144-1 REV=1. 5. INSTALLED FABRICATED PART IAW SRM 51-40-02-0G-0 REV=60 AND DWG 65B07872, SH=3 REV=D AND 65B07895 SH=10 REV=D 6. JOB COMPLETED AND CONDITION CHECK NORMAL.