What was found
BULK CARGO DOOR, INTERNAL STRUCTURE, CORROSION BTW BEAMS 2 AND 4.(<P>THE AREA WAS CLEANED, NEW SUPPORT WAS DRILLED, SUPPORT BEAM WAS INSTALLED. THE BEAM SUPPORT WAS REPLACED IAW SRM 51-10-02-0G-0. NO FURTHER DEFECTS NOTED</P>)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BULK CARGO DOOR, INTERNAL STRUCTURE, CORROSION BTW BEAMS 2 AND 4.(<P>THE AREA WAS CLEANED, NEW SUPPORT WAS DRILLED, SUPPORT BEAM WAS INSTALLED. THE BEAM SUPPORT WAS REPLACED IAW SRM 51-10-02-0G-0. NO FURTHER DEFECTS NOTED</P>)