UPPER HALF OF FUSELAGE, TOP TCAS ANTENNA, FOUR CONNECTORS, WITH CORROSION.(<P>CONNECTORS WERE CLEANED AS CLIENT REQUIREMENT, CORROSION INHIBITING COMPOUND AV25 WAS USED AS PROTECION AGENT IAW SWPM 20-60-03. NO FURTHER DEFECTS NOTED</P>)