What was found
ENG 1, RH CORE COWL, UPPER STRIP WITH CORROSION. L: 2.500 IN, W: 1.000 IN.(<P>THE CORROSION METAL STRIP WAS REMOVED, THE NEW METAL STRIP WAS DRILLED AND WAS INSTALLED CORRECTLY. SRM 51-40-02-0G-0 REV 127 15DEC24 AND SRM 51-10-02-0G-0 PAR 9. LEVEL 1. NO FURTHER DEFECTS NOTED</P>)