DURING HFEC INSPECTION ON NOSE WHEEL WELL SIDE AND TOP PANEL, WEB AND STIFFENER AT STA 265-280, WL 140 FOUND TWIN FASTENER AND UNABLE TO SCAN AROUND(<P>FASTENER REMOVED AND REPLACED IAW B747-400F SRM 51-40-02 REV 102. WORK ACCOMPLISHED IAW EN 1008-25 REV 0. NO FURTHER DEFECTS NOTED.</P>)