What was found
DURING ACCOMPLISH EO 4453C449_CS LH CLOSEOUT PANEL REPLACEMENT FOUND I/B SIDE CANTED PRESSURE BULKHEAD WEB FASTENER HOLE CRACKED.(<P>WORK ACCOMPLISHED <SPAN>7075T6-0.125" & 7075T6-0.063" </SPAN><SPAN>IAW EN 1014-25 REV 0.</SPAN></P>)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING ACCOMPLISH EO 4453C449_CS LH CLOSEOUT PANEL REPLACEMENT FOUND I/B SIDE CANTED PRESSURE BULKHEAD WEB FASTENER HOLE CRACKED.(<P>WORK ACCOMPLISHED <SPAN>7075T6-0.125" & 7075T6-0.063" </SPAN><SPAN>IAW EN 1014-25 REV 0.</SPAN></P>)