What was found
CRACK - FOUND M/D FLOOR STRUCTURE TRACK SUBSTITUTE CRACK BETWEEN STA 980 TO STA 1000, LBL 75.92.(<P>1. ACCOMPLISHED W/S NO. 50160 (SRM 53-00-52-2R-13 REV 103). 2. JOB COMPLETED AND CONDITION CHECK NORMAL.</P>)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK - FOUND M/D FLOOR STRUCTURE TRACK SUBSTITUTE CRACK BETWEEN STA 980 TO STA 1000, LBL 75.92.(<P>1. ACCOMPLISHED W/S NO. 50160 (SRM 53-00-52-2R-13 REV 103). 2. JOB COMPLETED AND CONDITION CHECK NORMAL.</P>)