As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION - FOUND M/D FLOOR BEAMS TOP SURFACE CORROSION STA 1500 BETWEEN LBL 55 TO LBL 75.92.(<P>1. REMOVE AFFECTED FASTENERS TO GET ACCESS IAW SRM 51-40-02-0G-0 REV 103. 2. REPAIR DAMAGE AREA IAW SRM 53-00-51-2R-3 REV 103, W/S NO: 50169 AND EI NO: T2025A53M-489 REV 2. 3. INSTALL FASTENERS IAW SRM 51-40-02-0G-0 REV 103 AND DWG NO: 65B38075 SH 11 REV -. 4. CONDITION CHECK NORMAL AND JOB COMPLETED.</P>)