What was found
MDCC, FLOOR STRUCTURE, BS 986.5 BETWEEN LBL 24.75 TO L2 DOOR INNER CHORD WITH SURFACE CORROSION.(<P>PERFORMED PERMANENT REPAIR AT TRANSVERSAL FLOOR BEAM STA 986.5 BTW BL 0.00 AND LBL 50.00 UPPER HORIZONTAL FLANGE AS PER ENGINEERING ORDER CONTROL #25101-1 REV A. NO FURTHER DEFECTS NOTED.</P>)