What was found
EICAS MESSAGE CHKLIST ENG FAIL LIGHT DISPLAYED FOLLOWED BY LT ENG AUTO SHUTDOWN. EICAS MESSAGE ENG FUEL VALVE LT DISPLAYED IN FLT. FOUND LT ENG FUEL SPAR VALVE CB TRIPPED & NOT RESETTABLE. R & R LT ENG FUEL SPAR VALVE ACTUATOR PER AMM 28-22-02 & AIPC 28-22-02-01. OPS CHKD GOOD. PERFORMED ENG RUN IAW AMM 71-00-00 TEST #5. ALL PARAMETERS NORMAL & FUEL SPAR INDICATION NORMAL. 5 MIN RUN ACCOMPLISHED. LT ENG FUEL SPAR VALVE ELECTRONIC CONTROL & INDICATION TEST PER AMM 28-22-00-216-801, NO DEFECTS NOTED. DVI OF ACCESSIBLE WIRING, FOUND NO DEFECTS IAW AMM 20-60-03. C/W INFLT WINDMILLING INSPECTION PER AMM 71-00-00-200-804-H01. VERIFIED OIL PRESSURE & 10 PSI AT SHUTDOWN & ENG DID NOT WINDMILL FOR 2 HRS. DMS PLUG CLEANED & ENG RUN FOR 5 MINS. ALL PARAMETERS NORMAL.