What was found
CORROSION- BEAM, LT WING INBD L/E CAVITY LOWER PNL FWD SUPPORT BEAM INNER FACE, ILES 485. BLENDED OUT THE DAMAGED AREA IAW SRM 51-10-02-0G-0, REV 61. PERFORMED NDT INSPECTION, REFER TO JOB CARD ATTACHING SHEET 0462383. MEASURED REWORK AREA LENGTH= 1.2", WIDTH = 0.2", DEPTH= 0.005", ALLOWABLE IAW SRM 57-41-13-1A-1, FIG 101, DETAIL V, REV 61. APPLY PROTECTIVE COATING IAW SRM 51-20-01-0G-0 REV=61.