What was found
CORROSION- BEAM, LT WING INBD L/E CAVITY LOWER PANEL FWD SUPPORT BEAM INNER FACE, ILES 987. BLENDED OUT THE DAMAGED AREA IAW SRM 51-10-02-0G-0, REV 61. PERFORMED NDT INSPECTION, REFER TO JOB CARD ATTACHING SHEET 0462387. MEASURED REWORK AREA LENGTH= 3.2", WIDTH = 0.9", DEPTH= 0.001", ALLOWABLE IAW SRM 57-41-13-1A-1, FIG 101, DETAIL V, REV 61. APPLY PROTECTIVE COATING IAW SRM 51-20-01-0G-0 REV=61.