What was found
CORROSION FOUND AT STA 1720 S44L SKIN INNER SURFACE ( APPROX 2.5" X 2.25" )(<P>CORROSION REMOVED AS PER SRM 51-10-02 AND REPROTECTED AS PER SRM 51-20-01, REWORK AREA MEASURED ORG: 0.071", L: 6" X W: 2.5" X D: 0.006", WITHIN SRM 53-00-01-1A-1 ALLOWABLE DAMAGE 1 FIG 101 LIMITS. NO FURTHER DEFECTS NOTED</P>)