What was found
M/D RHS BS 980 TO 1000 STR 15R TO STR 16R FX SKIN INT FOUND CORROSION(<P>CORROSION REMOVED AS PER SRM 51-10-02 AND REPROTECTED AS PER SRM 51-20-01, REWORK AREA MEASURED ORG: 0.150" L: 6" X W: 1.5" X D: 0.014", WITHIN SRM 53-00-01-1A-1 ALLOWABLE DAMAGE 1 FIG 101 LIMITS. NO FURTHER DEFECTS NOTED</P>)