What was found
DURING HFEC OPEN HOLE INSPECTION ON LHS STA 920 TENSION TIE AND FRAME, FOUND 01EA FASTENER HOLE ON AFT CHANNEL WITH CRACK. CRACKED TENSION TIE AFT CHANNEL ON LHS STA 920 TRIMMED OUT AND SPLICE REPAIR CARRIED OUT IAW SRM 53-20-30-2R-1, REPAIR 1, FIGURE 201, BS 720 - 920, REV. 107. REPAIR CLASSIFIED AS MAJOR REPAIR IAW GMM CHAPTER 5, FIGURE 5.3.2, VERSION 31. REPAIR CATEGORIZED AS "CATEGORY B" PERMANENT REPAIR.