As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
SMOKE IN CREW REST EICAS AT 1955Z FOR ABOUT 5 MINS. SMOKE DISSIPATED AND EICAS DID NOT RETURN. REPLACED ALL PACK WATER SEPERATOR COALESCER BAGS IAW AMM 05-51-56 AND FIM 21-00 TASK 810. REPLACED CREW REST AREA SMOKE DETECTOR IAW AMM 26-14-51 AND 21-51-05. NO SMOKE, FUMES, OR ELECTRICAL FAULT IN THE CABIN NOTED.</P>)