As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING OPEN HOLE INSPECTION AT RIGHT UPPER SPLICE FITTING AT STA2598 BULKHEAD, FOUND 01 EA ELONGATED HOLE AND 02 EA HOLES WITH CRACK INDICATION AT 9 O'CLOCK POSITION VIEW LOOKING INBD.(<P>REF TO EN 3842-26 REV.0 FOR WORK PERFORMED. NO FURTHER DEFECTS NOTED.</P>)