What was found
INSPECTION TYPE:C DURING ACCOMPLISHMENT OF EVACUATION SLIDE FLOOR MOUNTED BRACKET INSTALLATION CORROSION WAS DISCOVERED OUTSIDE LIMITS AT BS 312 LBL 46. REPAIR CARRIED OUT IAW SRM 53-10-8 FIG 7.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C DURING ACCOMPLISHMENT OF EVACUATION SLIDE FLOOR MOUNTED BRACKET INSTALLATION CORROSION WAS DISCOVERED OUTSIDE LIMITS AT BS 312 LBL 46. REPAIR CARRIED OUT IAW SRM 53-10-8 FIG 7.