What was found
INSPECTION TYPE:C, WHILE WORKING NRC 051193, FOUND CORROSION ON FRAME BS 600, RBL 8 WL 153. REPAIRED FRAMED PER SRM 53-10-2, 53-10-4, 51-30-2, MM 51-20-131.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C, WHILE WORKING NRC 051193, FOUND CORROSION ON FRAME BS 600, RBL 8 WL 153. REPAIRED FRAMED PER SRM 53-10-2, 53-10-4, 51-30-2, MM 51-20-131.