What was found
INSPECTION TYPE:C WHILE WORKING CARD B727-5310-1371E, FOUND CORROSION ON FRAME AT BS 425 BL 0 WL 146 AROUND E & E BAY DOOR FWD LATCH FITTING. REMOVED CORROSION ON FRAME AT BS 425 IN A AREA 3 X 3 X .040 DEEP ORIG THICKNESS IS .040, FOUND TO BE OUT OF LIMITS IAW SRM 53-10-1. REMOVED FRAME, ROUTED FRAME AND MATERIAL TO OUTSIDE SERVICES 7075-0. 040. FABRICATED FRAME TO .040 70 75-T6. INSTALLED NEW FRAME WET WITH SEALANT PER SRM 51-30-2, SRM 51-30-5, SRM 51- 20-4.