What was found
INSPECTION TYPE:C+SI, CRACK ON SPLICE ANGLE UNDER FLOOR AT BS 1180 I/B OF STR 17 RT IN LWR AFT CARGO HOLD. REPLACED CRACKED SPLICE ANGLE IAW SRM 51-20-1, SRM 51-30-2 & SRM 51-10-01.