What was found
INSPECTION TYPE:C&SI, NR 5 FLAP TRACK FWD SUPPORT FITTING UPPER HOLE HAS PITTING CORROSION. REPAIR CARRIED OUT IAW SMRO EO 2000-018-002 UPS ENGINEERING FILE NR 727-57-2160.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C&SI, NR 5 FLAP TRACK FWD SUPPORT FITTING UPPER HOLE HAS PITTING CORROSION. REPAIR CARRIED OUT IAW SMRO EO 2000-018-002 UPS ENGINEERING FILE NR 727-57-2160.