What was found
INSPECTION TYPE:C&SI, NR 4 FLAP TRACK FWD SUPPORT FITTING UPPER HOLE HAS PITTING CORROSION. REPAIR CARRIED OUT IAW SMRO EO 2000-018-001 UPS ENGINEERING FILE NOL 727-57-2159.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C&SI, NR 4 FLAP TRACK FWD SUPPORT FITTING UPPER HOLE HAS PITTING CORROSION. REPAIR CARRIED OUT IAW SMRO EO 2000-018-001 UPS ENGINEERING FILE NOL 727-57-2159.