What was found
INSPECTION TYPE:C, FLOORBEAM LOWER CHORD CORRODED BS 600 LBL 12 TO 14. CORROSION REMOVED PER SRM 51-10-06, FLOORBEAM REPAIRED IAW SMRO EO 2000-018-006, UPS ENGINEERING FILE NUMBER 727-53-2257.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C, FLOORBEAM LOWER CHORD CORRODED BS 600 LBL 12 TO 14. CORROSION REMOVED PER SRM 51-10-06, FLOORBEAM REPAIRED IAW SMRO EO 2000-018-006, UPS ENGINEERING FILE NUMBER 727-53-2257.