What was found
INSPECTION TYPE:C+SI SUSPECT CRACK ON BS 178 BULKHEAD LT STR 17L. HFEC INSPECTION CARRIED OUT IAW B727-NDT MANUAL, PT6,51-00-00,FIG4. CRACK CONFIRMED ON BS 178 BULKHEAD LT ANGLE, AT STR 17L. CRACK CUT OUT IAW SRM 51-40-3 FIG1 .HFEC INSP C/O IAW B727 NDT MANUAL,PT6,51-00-00, FIG4 AFTER DAMAGE REMOVED. NO DEFECT FOUND.