What was found
INSPECTION TYPE: C+SI, NR 3 FLAP TRACK FWD ATTACH LUG CORRODED. MACHINED AREA TO REMOVE CORROSION. MPI C/O ON THE FWD ATTACH LUGS IAW B727 SOP D6-51702 CHP 20-20-01.NDF. REF SMRO EO.2000-022-006 FOR REP AIR UPS FILE NR .727-57-2164.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C+SI, NR 3 FLAP TRACK FWD ATTACH LUG CORRODED. MACHINED AREA TO REMOVE CORROSION. MPI C/O ON THE FWD ATTACH LUGS IAW B727 SOP D6-51702 CHP 20-20-01.NDF. REF SMRO EO.2000-022-006 FOR REP AIR UPS FILE NR .727-57-2164.