As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:SI, CORROSION (C53-111-01.00-03) FWD CARGO BAY BS 660 FLOORBEAM FWD SIDE UPPER FLANGE LOWER SURFACE AT LBL 45 TO LBL 50. REMOVED CORROSION IN DESCREPANT AREA AT LBL 45 IN A 2.4 X 1.0 X .030 ORIGINAL THICKNESS .240 OUT OF LIMITS. REMOVED UPPER CHORD OF FLOORBEAM AT BS 660 LBL 8-LBL 72. FABRICATED NEW UPPER CHORD AND REPAIR PARTS AND INSTALLED IAW SRM 53-10-8 AND SRM 51-30-2.