What was found
INSPECTION TYPE:C 44, BS 400, STR 44 AREA LEFT AND RIGHT IN NOSE LANDING GEAR BAY, THE SPLICE PLATES AT BOTH LEFT AND RIGHT AFT CORNERS WERE CRACKED. REPAIR ACCOMPLISHED PER EO B747-5330-3520-D, SECTION 5, APPENDIX B. INSTALLED SKIN AND SPLICE STRAP DOUBLERS PER DRG 141U1099. CRACKED SPLICE PLATES REPLACED.