What was found
INSPECTION TYPE:C 44, UPPER DECK, FUSELAGE FRAME WEB IS CRACKED AT CUTOUT FOR STR AT BS 460 STR 11 RT. REPAIRED IAW SRM 53-10-04 FIG 20. STOP DRILLED IAW 51-10-01 AND REPAIR DOUBLER FITTED PER APPROVED 8110-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C 44, UPPER DECK, FUSELAGE FRAME WEB IS CRACKED AT CUTOUT FOR STR AT BS 460 STR 11 RT. REPAIRED IAW SRM 53-10-04 FIG 20. STOP DRILLED IAW 51-10-01 AND REPAIR DOUBLER FITTED PER APPROVED 8110-3.