What was found
INSPECTION TYPE:C, UPPER DECK FRAME WEB IS CRACKED AT CUTOUT FOR STR AT BS 480, 12 RT. REPAIR CARRIED OUT IAW QUERY NOTE 23/2000 AND SRM 53-10-04 FIG 22. TRIMMED OUT DAMAGED AREA AND FABRICATED REPAIR DOUBLERS, APPROVED 8110 ISSUED FOR REPAIR.