What was found
INSPECTION TYPE:C, CORROSION FOUND ON WINDOW FORGING BS 860 - 880 LT SIDE. FORGING REMOVED IAW SRM 51-30-02, CORROSION REMOVED IAW SRM 51-10-01 & 56-20-01, DEPTH OF CORR .009. FORGING REFITTED IAW SRM 51-30-02, BLEND OUTS ACCOMPLISHED IAW QUERY NOTE 43/2000.