What was found
INSPECTION TYPE:C, CABIN WINDOW FORGING CORRODED AT BS 1416 TO BS 1438 LT. FORGING REMOVED IAW SRM 51-30-02. CORROSION REMOVED IAW SRM 51-10 -01. DEPTH OF CORROSION REMOVED IS .010 IAW SRM 56-20-01 FORGING REFITTED IAW SRM 51-30-02 AND QUERY NOTE 65/2000 WHICH IS TO OVERSIZE HOLES BY .0156 AND PERFORM AN OPEN HOLE HFEC TO ENSURE HOLES ARE CRACK FREE AND MAINTAIN MIN EDGE MARGIN OF 1.5D.