What was found
INSPECTION TYPE:C, CABIN WINDOW FORGING CORRODED AT BS 1460 TO BS 1480 LT. FORGING REMOVED IAW SRM 51-30-02 AND CORROSION REMOVED IAW SRM 51-10-01. CORROSION REMOVED .010 IAW SRM 56-20-01. FORGING REFITTED IAW SRM 51-30-02 AND QUERY NOTE 41/2000 WHICH IS TO OVERSIZE HOLES BY 1/64 AND PERFORM AN OPEN HOLE HFEC FOR CRACKS ON HOLES COMMON TO FORGING AND SKIN. MAINTAIN MIN EDGE MARGIN OF 1.5D.