What was found
INSPECTION TYPE:C, CABIN WINDOW FORGING CORRODED AT BS 1540 TO BS 1560 LT. FORGING REMOVED IAW SRM 51-30-02 AND CORROSION REMOVED IAW SRM 51-10-01. DEPTH OF CORROSION REMOVED IS .009 IAW SRM 56-20-01. FORGING REFITTED IAW SRM 51-30-02 AND QUERY NOTE 36/2000 WHICH IS TO OVERSIZE HOLES BY 1/64 AND PERFORM OPEN HOLE HFEC, ENSURE MIN EDGE MARG IN OF 1.5D ON ALL HOLES EXCEPT HOLES A, B AND C AS SPECIFIED.