What was found
INSPECTION TYPE:C, CABIN WINDOW FORGING CORRODED AT BS 1560 TO BS 1580 LT. FORGING REMOVED IAW SRM 51-30-02 AND CORROSION REMOVED IAW SRM 51-10-01. DEPTH CORROSION REMOVED IS .009 IAW SRM 56-20-01. FORGING REFITTED IAW SRM 51-30-02 AND QUERY NOTE 66/2000 WHICH IS TO OVERSIZE HOLES BY 1/64 AND PERFORM OPEN HOLE HFEC FOR CRACKS. MIN EDGE MARGIN IS 1.5D REPAIR/ALTERATION AUTHORIZATION EFN 747-53-1130.