What was found
INSPECTION TYPE:C, DOOR NR 4 LT FWD FRAME, BETWEEN UPPER HINGE CUTOUT AND STOP NR 5 FROM TOP, IS DAMAGED. DAMAGE CLEANED UP AND WITHIN SRM LIMITS IAW SRM 53-10-01 AND AREA REPROTECTED IAW SRM 51-10-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C, DOOR NR 4 LT FWD FRAME, BETWEEN UPPER HINGE CUTOUT AND STOP NR 5 FROM TOP, IS DAMAGED. DAMAGE CLEANED UP AND WITHIN SRM LIMITS IAW SRM 53-10-01 AND AREA REPROTECTED IAW SRM 51-10-02.