What was found
INSPECTION TYPE:N/A, DIVERSION - APU SHUTDOWN IN FLIGHT. SHUTDOWN FAULT LIGHT WENT RESTART SHUT DOWN AGAIN. WOULD NOT RESTART. REMOVED AND REPLACED APU FLOW SENSING MODULE PER MM 49-53-08, OPS CK GOOD ON 15 MIN RUN.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:N/A, DIVERSION - APU SHUTDOWN IN FLIGHT. SHUTDOWN FAULT LIGHT WENT RESTART SHUT DOWN AGAIN. WOULD NOT RESTART. REMOVED AND REPLACED APU FLOW SENSING MODULE PER MM 49-53-08, OPS CK GOOD ON 15 MIN RUN.