What was found
INSPECTION TYPE:C123 IN NR 2 MAIN TANK ACCESS 505F JUST I/B OF XRS 74 STRINGER 51 END FITTING WAS CRACKED. REMOVED CRACKED FITTING, REV'D NEW FITTING (P/N 3704841-1), LOCATED AND DRILLED IAW DC8 SRM 51-1-24, ALODINED AND PRIMED IAW DC8 SRM 51-1-8. INSTALLED FITTING IAW DC8 SRM 51-1-20D AND 51-3-0, SEALED IAW DC8 SRM 51- 1-12.